01The problem

  • 300m² gym on the upper level of Richmond Mall, with retail tenancies directly below.
  • Noise and impact transfer to the lower level from gym equipment.
  • Impact noise is structure-borne: it starts in the floor itself and radiates into the rooms underneath, so treating the gym’s walls or ceiling would have done nothing for the tenancies below.
  • That left the floor build-up as the only place to deal with it, and the finish still had to stand up to dropped weights and constant foot traffic.

02The solution

  • Supplied and installed 15mm rubber underlay under polypropylene carpet to absorb impact before it reaches the shops below.
  • The rubber layer does the acoustic work: a resilient underlay beneath the finished floor absorbs impact energy where it is created and decouples the walking surface from the structure that would otherwise carry it downwards.
  • Rubber keeps isolating under the point loads a gym puts on a floor, where a soft foam-type underlay compresses and stops working — which is why rubber is the usual choice beneath gym surfaces.
  • Polypropylene carpet over the top takes the daily wear, adds a little absorption inside the gym itself, and gives a hard-wearing, low-maintenance training surface.